Mining Rescue Cabin

Technical description Rescue Cabin

1. Model of Rescue Cabin KJY – 96/6 (6 persons)

1.1. Applied Conditions:  
• Temperature: 550 (10 hours), 250 (96+20%hours)
• Humidity: 0 – 95%
• Atmospheric Pressure: 80 – 106 кPа
• Altitude: ≤1000m

Location

Laying Position: 500m away from the mining face underground with the risk of collapse and gas

1.3. Model:

  • • KJ – Movable Mining Rescue Cabin
  • • Y – With Hard Shell
  • • 96 – Protection Time (h)
  • • 6 – Number of People

1.4. Main Parameters

• Rated Number of People: 6 persons
• Rated Protection Time: 96 h
• Impact Resistance: 0,3 МPа
• Sustainable High Temperature Resistance: 10h at 55°C
• Instantaneous High Temperature Resistance (°C) ≈12000
• Pressure 100Pa – 500Pa
• Dimensions (L×W×H): 8408mm х 1440mm х 1900mm
• Weight: 17.7 тн
• Service Life: 10 лет

Conditions in the box-base

Safety Factor during Protection Time – 1,2

Per Capita Capacity Oxygen Concentration Carbon Monoxide Concentration Carbon Dioxide Concentration Methane Concentration Temperature Humidity
0,8 m3 18.5 – 23% 0.0024% 1.0% 1.0% 350 85%

This mining rescue cabin possesses the functions of temperature reduction, anhydration and air purification.

Main Elements of the Components.

3.1. Appearance.

3.2. Oxygen Supply System.

  • Supply of Compressed Oxygen.
  • Supply of Medical Oxygen.
  • Rescue Mode: Oxygen Supply.

3.3. Measurement-Control System.

  • Measurement Equipment CD4.
  • Air Detector.
  • Measurement Pipe of Carbon Dioxide.
  • Measurement Euipment of Tempeature - Humidity.
  • Pressure Measurement Device.
  • Telephone Conneted with the Rescue Cabin.
  • Exterior Lighting.
  • Phosphorescent light is adopted in the rescue cabin.
  • Miner's Lamp Used after Escaping from the Rescue Cabin.

3.4 Lfie Surpport System.

  • Rye Bread.
  • Drinking Water.
  • First-aid Kit.
  • Rescue Vehicle (to help with breath).
  • Tool-Kit.
  • Fire Extinguisher A = 1000 mm; B = 2800 mm; C = 2900 mm; D = 1900 mm; E = 1140 mm; F = 6870 mm.